Section Properties Calculator
Area, centroid, I, Z, J for standard sections.
Area
5,000 mm²
Second moment Iₓ
4,166,667 mm⁴
All results and steps ↓
Section
mm
Flange width for I, T and channel
mm
Diagram
Results
Area
5,000mm²
Second moment Iₓ
4,166,667mm⁴
Section modulus Sₓ
83,333mm³
Radius of gyration rₓ
28.87mm
Second moment IᵧIᵧ
1,041,667mm⁴
Section modulus SᵧSᵧ
41,667mm³
Radius of gyration rᵧrᵧ
14.43mm
Torsion constant (approximate (thin-wall / Saint-Venant))J
2,861,003mm⁴
Centroid from bottomȳ
50mm
Centroid from leftx̄
25mm
Distance to top fibre
50mm
Distance to bottom fibre
50mm
Calculation steps
- 1AreaA = ΣAᵢA = 5,000 mm²
- 2Centroidȳ = ΣAᵢ·yᵢ / Aȳ = 50 mm
- 3Second moment (parallel-axis theorem)Iₓ = Σ(Iᵢ + Aᵢ·dᵢ²)Iₓ = 4,166,667 mm⁴
- 4Section modulusSₓ = Iₓ / c_maxc_max = 50 mmSₓ = 83,333 mm³
Assumptions & limitations
- Sharp-cornered idealised shapes built from rectangles (no fillets).
- x-axis horizontal through the centroid.
Limitations
- Rolled shapes with root fillets and tapered flanges differ slightly — use published section tables for standard profiles.
- Torsion constant is approximate for non-circular sections; warping constant not computed.
Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.