Art and Engineering

Pressure Drop Calculator

Darcy–Weisbach pressure drop with fittings.

Total pressure drop
17.82 kPa
Head loss
1.82 m
All results and steps ↓

Fluid

kg/m³
mPa·s

Pipe

L/min
mm
mm
m
m

Fittings (count)

Diagram

2 elbowsp₁p₂L = 30 m · D = 50 mm · Q = 180 L/minΔp = p₁ − p₂ = friction + fittings + elevation

Results

Total pressure drop
17.82kPa
Head loss
1.82m
Mean velocity
1.528m/s
Hydraulic power
0.05345kW
divide by pump efficiency for shaft power
Friction loss (pipe)
15.72kPa
Fitting losses (ΣK = 1.8)
2.097kPa
Elevation
0kPa
Reynolds numberRe
76,105
Darcy friction factorf
0.02249

Calculation steps

  1. 1Velocity and Reynolds number
    v = 4Q/(πD²), Re = ρvD/μ
    v = 1.528 m/s, Re = 76,105
  2. 2Friction factor
    Colebrook–White
    ε/D = 0.0009
    f = 0.02249
  3. 3Pipe friction loss
    Δp_f = f·(L/D)·ρv²/2
    L = 30 m
    Δp_f = 15.72 kPa
  4. 4Fitting losses
    Δp_K = ΣK·ρv²/2
    ΣK = 1.8
    Δp_K = 2.097 kPa
  5. 5Elevation
    Δp_z = ρ·g·Δz
    Δz = 0 m
    Δp_z = 0 kPa
  6. 6Total
    Δp = Δp_f + Δp_K + Δp_z
    Δp = 17.82 kPa
Assumptions & limitations
  • Steady incompressible flow, constant diameter; Darcy–Weisbach with Colebrook friction factor.
  • Fitting K values are typical constants; real values depend on size, type and Reynolds number.
Limitations
  • Not for compressible gas flow with large pressure change, cavitation or two-phase flow.
  • Use manufacturer data for valves, strainers and equipment pressure drops.

Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.