Pressure Drop Calculator
Darcy–Weisbach pressure drop with fittings.
Total pressure drop
17.82 kPa
Head loss
1.82 m
All results and steps ↓
Fluid
kg/m³
mPa·s
Pipe
L/min
mm
mm
m
m
Fittings (count)
Diagram
Results
Total pressure drop
17.82kPa
Head loss
1.82m
Mean velocity
1.528m/s
Hydraulic power
0.05345kW
divide by pump efficiency for shaft power
Friction loss (pipe)
15.72kPa
Fitting losses (ΣK = 1.8)
2.097kPa
Elevation
0kPa
Reynolds numberRe
76,105
Darcy friction factorf
0.02249
Calculation steps
- 1Velocity and Reynolds numberv = 4Q/(πD²), Re = ρvD/μv = 1.528 m/s, Re = 76,105
- 2Friction factorColebrook–Whiteε/D = 0.0009f = 0.02249
- 3Pipe friction lossΔp_f = f·(L/D)·ρv²/2L = 30 mΔp_f = 15.72 kPa
- 4Fitting lossesΔp_K = ΣK·ρv²/2ΣK = 1.8Δp_K = 2.097 kPa
- 5ElevationΔp_z = ρ·g·ΔzΔz = 0 mΔp_z = 0 kPa
- 6TotalΔp = Δp_f + Δp_K + Δp_zΔp = 17.82 kPa
Assumptions & limitations
- Steady incompressible flow, constant diameter; Darcy–Weisbach with Colebrook friction factor.
- Fitting K values are typical constants; real values depend on size, type and Reynolds number.
Limitations
- Not for compressible gas flow with large pressure change, cavitation or two-phase flow.
- Use manufacturer data for valves, strainers and equipment pressure drops.
Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.