Required peak motor torque
9.912 N·m
Continuous motor torque
6.944 N·m
All results and steps ↓

Load

N·m
rpm
kg·m²
s

Drive

%

Spur/helical ~95–98% per stage, worm 40–90%

kg·m²

From motor datasheet (0 if unknown)

Diagram

Motori = 10 · η = 90%J_L = 0.5 kg·m²T_L = 50 N·m150 rpm1,500 rpm

Results

Required peak motor torque
9.912N·m
Continuous motor torque
6.944N·m
Motor speed
1,500rpm
Continuous motor power
0.8727kW
Peak power
1.557kW
Load torque at motor
5.556N·m
Acceleration torque
2.374N·m
Reflected load inertia
0.005556kg·m²
Inertia ratio (reflected : motor)
2.778: 1
Inertia-matched ratio √(J_L/J_M)
15.81

Calculation steps

  1. 1Motor speed
    n_m = i·n_out
    10 × 150 rpm
    n_m = 1,500 rpm
  2. 2Load torque at motor
    T_L,m = T_L / (i·η)
    50 N·m / (10·0.9)
    5.556 N·m
  3. 3Reflected inertia
    J_ref = J_L / (i²·η)
    0.005556 kg·m²
  4. 4Acceleration torque
    T_acc = (J_M + J_ref)·ω_m/t
    ω_m = 157.1 rad/s, t = 0.5 s
    2.374 N·m
  5. 5Peak torque
    T_peak = SF·(T_L,m + T_acc)
    SF = 1.25
    9.912 N·m
  6. 6Continuous power
    P = T_L,m·ω_m
    0.8727 kW
Assumptions & limitations
  • Rigid drive train, constant acceleration from rest; efficiency applied to load torque and reflected inertia.
  • Continuous torque taken as the service-factored running load torque (no duty-cycle RMS).
Limitations
  • Duty-cycle RMS torque, motor thermal limits, gearbox ratings and compliance are not evaluated.
  • Select final components from manufacturer data.

Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.