Art and Engineering

Buckling Calculator

Euler and Johnson column buckling.

Critical buckling load
819,702 N
Safety factor
40.99
All results and steps ↓

Column

m
N

Cross-section

mm

Flange width for I, T and channel

mm

Material

GPa
MPa

Diagram

P = 20,000 NL = 1.5 mbuckled shape, K = 1Section

Results

Critical buckling load
819,702N
Safety factor
40.99
Slenderness ratio
103.9
Method
Johnson
Transition slenderness(KL/r)_t
126.1
Least radius of gyrationr
14.43mm
Least second moment of areaI_min
1,041,667mm⁴
AreaA
5,000mm²
Euler load (reference)
913,852N

Calculation steps

  1. 1Radius of gyration
    r = √(I_min/A)
    I_min = 1,041,667 mm⁴, A = 5,000 mm²
    r = 14.43 mm
  2. 2Slenderness
    λ = K·L/r
    K = 1, L = 1.5 m
    λ = 103.9
  3. 3Transition slenderness
    λₜ = √(2π²E/Sᵧ)
    λₜ = 126.1
  4. 4Johnson critical load (λ < λₜ)
    P_cr = A·[Sᵧ − (Sᵧ·λ/(2π))²/E]
    Sᵧ = 248.2 MPa
    P_cr = 819,702 N
  5. 5Safety factor
    n = P_cr / P
    n = 41
Assumptions & limitations
  • Initially straight, concentrically loaded, prismatic column; buckling about the weakest axis.
  • Johnson parabola below the transition slenderness, Euler above.
Limitations
  • Eccentric loads (secant formula), local buckling of thin walls and code column curves (AISC/Eurocode) are not included.
  • Theoretical K values assume ideal end restraint.

Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.