Buckling Calculator
Euler and Johnson column buckling.
Critical buckling load
819,702 N
Safety factor
40.99
All results and steps ↓
Column
m
N
Cross-section
mm
Flange width for I, T and channel
mm
Material
GPa
MPa
Diagram
Results
Critical buckling load
819,702N
Safety factor
40.99
Slenderness ratio
103.9
Method
Johnson
Transition slenderness(KL/r)_t
126.1
Least radius of gyrationr
14.43mm
Least second moment of areaI_min
1,041,667mm⁴
AreaA
5,000mm²
Euler load (reference)
913,852N
Calculation steps
- 1Radius of gyrationr = √(I_min/A)I_min = 1,041,667 mm⁴, A = 5,000 mm²r = 14.43 mm
- 2Slendernessλ = K·L/rK = 1, L = 1.5 mλ = 103.9
- 3Transition slendernessλₜ = √(2π²E/Sᵧ)λₜ = 126.1
- 4Johnson critical load (λ < λₜ)P_cr = A·[Sᵧ − (Sᵧ·λ/(2π))²/E]Sᵧ = 248.2 MPaP_cr = 819,702 N
- 5Safety factorn = P_cr / Pn = 41
Assumptions & limitations
- Initially straight, concentrically loaded, prismatic column; buckling about the weakest axis.
- Johnson parabola below the transition slenderness, Euler above.
Limitations
- Eccentric loads (secant formula), local buckling of thin walls and code column curves (AISC/Eurocode) are not included.
- Theoretical K values assume ideal end restraint.
Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.