Bolt Calculator
Preload, torque and joint stiffness.
Tightening torque
50.45 N·m
Preload
25,225 N
All results and steps ↓
Bolt
Tightening
%
75% reusable joints, 90% permanent (common guideline)
≈ 0.20 dry steel, 0.15–0.18 lubricated, 0.10–0.12 anti-seize (typical)
Joint
N
Diagram
Results
Tightening torque
50.45N·m
Preload
25,225N
Tensile stress area
57.99mm²
Proof load
33,634N
Proof strengthSₚ
580MPa
Minimum tensile strengthSᵤₜ
800MPa
Calculation steps
- 1Tensile stress areaAₜ = π/4·((d₂ + d₃)/2)²d = 10 mm, pitch = 1.5 mmAₜ = 57.99 mm²
- 2PreloadFᵢ = (preload %)·Aₜ·Sₚ75% × 57.99 mm² × 580 MPaFᵢ = 25,225 N
- 3Tightening torqueT = K·Fᵢ·d0.2 × 25,225 N × 10 mmT = 50.45 N·m
Assumptions & limitations
- Torque–tension relation T = K·F·d with a single nut factor; actual preload scatter is typically ±25% with a torque wrench.
- Minimum strengths per ISO 898-1 / SAE J429 as listed.
Limitations
- Does not calculate joint stiffness, thread stripping, embedding, fatigue or prying.
- Always prefer the fastener or equipment manufacturer's torque specification where available.
Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.