Art and Engineering

Bolt Calculator

Preload, torque and joint stiffness.

Tightening torque
50.45 N·m
Preload
25,225 N
All results and steps ↓

Bolt

Tightening

%

75% reusable joints, 90% permanent (common guideline)

≈ 0.20 dry steel, 0.15–0.18 lubricated, 0.10–0.12 anti-seize (typical)

Joint

N

Diagram

Fᵢ (preload)T (tightening torque)M10class 8.8K = 0.2

Results

Tightening torque
50.45N·m
Preload
25,225N
Tensile stress area
57.99mm²
Proof load
33,634N
Proof strengthSₚ
580MPa
Minimum tensile strengthSᵤₜ
800MPa

Calculation steps

  1. 1Tensile stress area
    Aₜ = π/4·((d₂ + d₃)/2)²
    d = 10 mm, pitch = 1.5 mm
    Aₜ = 57.99 mm²
  2. 2Preload
    Fᵢ = (preload %)·Aₜ·Sₚ
    75% × 57.99 mm² × 580 MPa
    Fᵢ = 25,225 N
  3. 3Tightening torque
    T = K·Fᵢ·d
    0.2 × 25,225 N × 10 mm
    T = 50.45 N·m
Assumptions & limitations
  • Torque–tension relation T = K·F·d with a single nut factor; actual preload scatter is typically ±25% with a torque wrench.
  • Minimum strengths per ISO 898-1 / SAE J429 as listed.
Limitations
  • Does not calculate joint stiffness, thread stripping, embedding, fatigue or prying.
  • Always prefer the fastener or equipment manufacturer's torque specification where available.